Multi Parameter Monitors Colin BP-S510 Patient Monitor

Price : $2100

Leading-edge patient monitor features patented Colin NIBP technology
The BP-S510 has a sophisticated design that provides simple, user-friendly operation. Its advanced functionality makes it perfect for a wide variety of uses, including post-anesthesia care, ambulatory surgery, endoscopy, emergency rooms and more!
    * Measures ECG (3/5 lead), heart rate, Colin NIBP, Nellcor SpO2 and respiration. Available with temperature, two-channel IBP, EtCO2, and a printer.
    * Compact: Conveniently compact and feature-packed, the BP-S510 is great for areas where space is at a premium.
    * Lightweight: Weighing only 12.1 lbs, the BP-S510 is easy to carry from ward to ward. This lightweight device makes it easy to move to stepdown, PACU, RR, etc.
    * Battery Operation for Portability: Available with rechargeable batteries, the BP-S510 can be used during transport within your facility.
    * Wide Viewing Angle: The BP-S510’s large LCD screen features a wide viewing angle. Each parameter is color-coded in bright and vivid colors, making the information easy to read even from a distance. You can also select from multiple views to highlight just the information you need.

Technical Specifications
Non-Invasive Blood Pressure (NIBP) - Patented Colin Technology
    * Measurement technology Oscillometric method
    * Measurement method Linear deflation method
    * Pressure display range 10 to 300mmHg
    * Pressure display accuracy Less than ±3mmHg
    * NIBP Measurement range
    * Adult/pediatric mode

SYS 60 to 250mmHg
MAP 45 to 235mmHg
DIA 40 to 200mmHg
Pulse rate 40 to 200bpm
    * Pulse rate 40 to 240bpm
    * NIBP accuracy AAMI SP-10:2002+A1:2003
    * Pulse rate accuracy ±2% or ±2 beats

ECG (Electrocardiogram)
    * Leads 3/5 Lead
    * Lead I, II, III, aVR, aVL, aVF, V (Chest Lead)
    * Heart Rate
    * Measurement Range 20 to 250bpm
    * Accuracy ±3bpm or ±5% (whichever is greater)

Respiration (im RR)
    * Measurement method Trans-thoracic impedance
    * Leads RA to LA
    * Range 0, 3 to 120breaths/min
    * Accuracy ±3 breaths/min

SpO2 (Pulse oximeter)
    * Measurement method 2 wave length pulse wave type
    * Range 1 to 100% SpO2
    * Accuracy Adult/pediatric (When using SpO2 Disposable Sensor MAX-A) 70 to 100% SpO2 ±2 digits, 1 to 69% SpO2 unspecified
    * Pulse Rate Range 20 to 250bpm
    * Pulse Rate Accuracy ±3bpm
    * Display update Less than 30 sec

Temperature Measurement (Option)
    * Measurement method Thermistor
    * Probe Type Thermistor probe YSI 400 series (2 channels) (Probes not included)
    * Range 15 to 45°C (59 to 113°F)
    * Display Accuracy ±0.1°C (25 to 45°C) (77 to 113°F) ±0.2°C (15 to less than 25°C) (59 to less than 77°F)
    * Probe Accuracy ±0.1°C (±0.18°F)

IBP (Option)
    * Measurement Method: Pressure Transducer Method
    * Pressure Measurement Range - -50 to +300mmHG
    * Pulse Rate Measurement Range – 20 to 250bpm
    * Display Accuracy - ±3mmHG
    * Standard – IEC60601-2-34:2000

CO2 (Option)
    * Measurement method Non-dispersive Infrared Spectroscopy
    * Range 0-100mmHg : 0-13.3kpa : 0-10%CO2
    * Accuracy ±2mmHg or ±4% (whichever is greater)
    * Respiration (awRR) Range 0 to 120 breaths/min
    * Respiration (awRR) Accuracy ±1 breath/min

Recorder (Option)
    * Type Thermal
    * Weight 150g (0.33lbs)
    * Resolution 8 dot/mm
    * Number of channels 1 to 2 channels
    * Paper Type Thermal
    * Paper Width 50mm (2in)
    * Paper Speeds 25.0mm/sec and 50.0mm/sec (1in/sec and 2in/sec)

General
    * Dimensions 360(W) x 215(D) x 280(H)mm (14.2 x 8.5 x 11in)
    * Weight 5.5kg (12.1lbs) (excluding optional configurations and accessories)
    * Display - Screen Size 26.4cm (10.4in) measured diagonally, Screen Type/Color Liquid Crystal Display (LCD) color, Resolution 800 x 600 pixels
    * Number of traces 4 or 6 waveforms
    * Safety Standard IEC60601-1:1988+A1:1991+A2:1995
    * Degree of protection (enclosures) IP21
    * Type of protection Type CF - Applied part

Power Requirement
    * AC Power 100-240V~50/60Hz, 0.5-1.3A
    * Battery Ni-MH, 12V/3.8Ah (1 included)

Environmental
    * Operating Temperature 10 to 40°C (50 to 104°F)
    * Storage Temperature -20 to 60°C (-4 to 140°F)
    * Operating Humidity 15 to 90% RH, non-condensing

Accessories
Most models: Reusable adult cuff, adult 3.5m cuff hose, ECG cable,
ECG 3-lead wires, SpO2 Durasensor® DS-100A, SpO2 extension cable
DOC-10, operation manual, power cord, rechargeable battery (1).
Available with: CO2 sampling set, printer paper, ECG 5-lead wires,
temperature probes, rolling stand, and a full size range of reusable and
disposable BP cuffs