Price : $1,895.00
The Datascope Passport monitor measures ECG, Respiration, NIBP, SPO2, and Temperature. The Passport has a large electroluminescent screen for easy viewing from any angle. This monitor is operated with easy to use, single function keys. DRE sells the Passport refurbished.
Specifications:
* Dimension: 9.5" x 13" x 8" (H x W x L)
* Weight: 13 lbs. maximum without batteries
* Power Consumption: 15 watts typical
* Voltage input: 100, 120, 220, 240 VAC ± 10%
* Mains frequency: 47 to 65 Hz
ECG
* Leads: I, II, III
* Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ± 10%
* Frequency response to screen: ESU filter out: 0.5 to 40 Hz, -3db max @ 1 mVpp input; ESU filter in: 0.5 to 20 Hz -3db max @ 1 mVpp input
Heart Rate Meter
* Range: 30-300 bpm adult/child. 30-350 bpm neonatal
* Accuracy: 30-250 bpm ± 3bpm or 3%, whichever is greater.
* Pacer rejection: rejects all pulse of amplitude ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with no tail. Rejects all pulses ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with 100 ms T.C. tail <0.8 mV or 25 ms T.C. tail <0.4 mV.
* Display update: 2 seconds ± 0.1 sec
NIBP
* Technique: oscillometric
* Systolic range: adult/ped mode: 40-250 mmHg, neonate mode: 15-150 mmHg.
* Diastolic range: adult/ped mode: 30-200 mmHg, neonate mode: 10-150 mmHg.
* Systolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 3 mmHg, standard deviation less than 13 mmHg (neonatal).
* Diastolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 4 mmHg, standard deviation less than 7 mmHg (neonatal).
* Heart rate meter range: 30-250 bpm.
* Heart rate meter accuracy: ±3 bpm or ±3%, whichever is greater.
Pulse Oximetry
* Accuracy (1standard deviation): 70-100%, ±2%; 60-69%, ±4%; 0-59%, unspecified.
* Response time: 13 seconds to 95% of final step change % SpO2 value from 60-95% at 72 bpm
Recorder (optional)
* Speed: 50, 25, 12.5, 6.25, 3.125 mm/sec ±5%
* Note: 6.25 and 3.125 are for respiration only
* Chart size: 50 mm ±2mm
Battery Requirements
* 2 sealed lead batteries
* Voltage: 12 VDC
* Capacity: 2.3 AH each
* Run time: 2 hours fully charged battery
* Recharge time: 16 hours maximum
* Low battery warning: 11.6 ± 3.5%
* Low battery cut off: 11.0 ± 2.8%
Specifications:
* Dimension: 9.5" x 13" x 8" (H x W x L)
* Weight: 13 lbs. maximum without batteries
* Power Consumption: 15 watts typical
* Voltage input: 100, 120, 220, 240 VAC ± 10%
* Mains frequency: 47 to 65 Hz
ECG
* Leads: I, II, III
* Display sensitivity: 0.25, 0.5, 1.0, 2.0, 3.0, 4.0 cm/mV ± 10%
* Frequency response to screen: ESU filter out: 0.5 to 40 Hz, -3db max @ 1 mVpp input; ESU filter in: 0.5 to 20 Hz -3db max @ 1 mVpp input
Heart Rate Meter
* Range: 30-300 bpm adult/child. 30-350 bpm neonatal
* Accuracy: 30-250 bpm ± 3bpm or 3%, whichever is greater.
* Pacer rejection: rejects all pulse of amplitude ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with no tail. Rejects all pulses ± 2.0 mV to ± 700 mV and duration 0.1 ms to 2 ms with 100 ms T.C. tail <0.8 mV or 25 ms T.C. tail <0.4 mV.
* Display update: 2 seconds ± 0.1 sec
NIBP
* Technique: oscillometric
* Systolic range: adult/ped mode: 40-250 mmHg, neonate mode: 15-150 mmHg.
* Diastolic range: adult/ped mode: 30-200 mmHg, neonate mode: 10-150 mmHg.
* Systolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 3 mmHg, standard deviation less than 13 mmHg (neonatal).
* Diastolic accuracy: mean error less than 7 mmHg, standard deviation less than 8 mmHg (adult/pediatric). Mean error less than 4 mmHg, standard deviation less than 7 mmHg (neonatal).
* Heart rate meter range: 30-250 bpm.
* Heart rate meter accuracy: ±3 bpm or ±3%, whichever is greater.
Pulse Oximetry
* Accuracy (1standard deviation): 70-100%, ±2%; 60-69%, ±4%; 0-59%, unspecified.
* Response time: 13 seconds to 95% of final step change % SpO2 value from 60-95% at 72 bpm
Recorder (optional)
* Speed: 50, 25, 12.5, 6.25, 3.125 mm/sec ±5%
* Note: 6.25 and 3.125 are for respiration only
* Chart size: 50 mm ±2mm
Battery Requirements
* 2 sealed lead batteries
* Voltage: 12 VDC
* Capacity: 2.3 AH each
* Run time: 2 hours fully charged battery
* Recharge time: 16 hours maximum
* Low battery warning: 11.6 ± 3.5%
* Low battery cut off: 11.0 ± 2.8%