Price : $2100
Leading-edge patient monitor features patented Colin NIBP technology
The BP-S510 has a sophisticated design that provides simple, user-friendly operation. Its advanced functionality makes it perfect for a wide variety of uses, including post-anesthesia care, ambulatory surgery, endoscopy, emergency rooms and more!
* Measures ECG (3/5 lead), heart rate, Colin NIBP, Nellcor SpO2 and respiration. Available with temperature, two-channel IBP, EtCO2, and a printer.
* Compact: Conveniently compact and feature-packed, the BP-S510 is great for areas where space is at a premium.
* Lightweight: Weighing only 12.1 lbs, the BP-S510 is easy to carry from ward to ward. This lightweight device makes it easy to move to stepdown, PACU, RR, etc.
* Battery Operation for Portability: Available with rechargeable batteries, the BP-S510 can be used during transport within your facility.
* Wide Viewing Angle: The BP-S510’s large LCD screen features a wide viewing angle. Each parameter is color-coded in bright and vivid colors, making the information easy to read even from a distance. You can also select from multiple views to highlight just the information you need.
Technical Specifications
Non-Invasive Blood Pressure (NIBP) - Patented Colin Technology
* Measurement technology Oscillometric method
* Measurement method Linear deflation method
* Pressure display range 10 to 300mmHg
* Pressure display accuracy Less than ±3mmHg
* NIBP Measurement range
* Adult/pediatric mode
SYS 60 to 250mmHg
MAP 45 to 235mmHg
DIA 40 to 200mmHg
Pulse rate 40 to 200bpm
* Pulse rate 40 to 240bpm
* NIBP accuracy AAMI SP-10:2002+A1:2003
* Pulse rate accuracy ±2% or ±2 beats
ECG (Electrocardiogram)
* Leads 3/5 Lead
* Lead I, II, III, aVR, aVL, aVF, V (Chest Lead)
* Heart Rate
* Measurement Range 20 to 250bpm
* Accuracy ±3bpm or ±5% (whichever is greater)
Respiration (im RR)
* Measurement method Trans-thoracic impedance
* Leads RA to LA
* Range 0, 3 to 120breaths/min
* Accuracy ±3 breaths/min
SpO2 (Pulse oximeter)
* Measurement method 2 wave length pulse wave type
* Range 1 to 100% SpO2
* Accuracy Adult/pediatric (When using SpO2 Disposable Sensor MAX-A) 70 to 100% SpO2 ±2 digits, 1 to 69% SpO2 unspecified
* Pulse Rate Range 20 to 250bpm
* Pulse Rate Accuracy ±3bpm
* Display update Less than 30 sec
Temperature Measurement (Option)
* Measurement method Thermistor
* Probe Type Thermistor probe YSI 400 series (2 channels) (Probes not included)
* Range 15 to 45°C (59 to 113°F)
* Display Accuracy ±0.1°C (25 to 45°C) (77 to 113°F) ±0.2°C (15 to less than 25°C) (59 to less than 77°F)
* Probe Accuracy ±0.1°C (±0.18°F)
IBP (Option)
* Measurement Method: Pressure Transducer Method
* Pressure Measurement Range - -50 to +300mmHG
* Pulse Rate Measurement Range – 20 to 250bpm
* Display Accuracy - ±3mmHG
* Standard – IEC60601-2-34:2000
CO2 (Option)
* Measurement method Non-dispersive Infrared Spectroscopy
* Range 0-100mmHg : 0-13.3kpa : 0-10%CO2
* Accuracy ±2mmHg or ±4% (whichever is greater)
* Respiration (awRR) Range 0 to 120 breaths/min
* Respiration (awRR) Accuracy ±1 breath/min
Recorder (Option)
* Type Thermal
* Weight 150g (0.33lbs)
* Resolution 8 dot/mm
* Number of channels 1 to 2 channels
* Paper Type Thermal
* Paper Width 50mm (2in)
* Paper Speeds 25.0mm/sec and 50.0mm/sec (1in/sec and 2in/sec)
General
* Dimensions 360(W) x 215(D) x 280(H)mm (14.2 x 8.5 x 11in)
* Weight 5.5kg (12.1lbs) (excluding optional configurations and accessories)
* Display - Screen Size 26.4cm (10.4in) measured diagonally, Screen Type/Color Liquid Crystal Display (LCD) color, Resolution 800 x 600 pixels
* Number of traces 4 or 6 waveforms
* Safety Standard IEC60601-1:1988+A1:1991+A2:1995
* Degree of protection (enclosures) IP21
* Type of protection Type CF - Applied part
Power Requirement
* AC Power 100-240V~50/60Hz, 0.5-1.3A
* Battery Ni-MH, 12V/3.8Ah (1 included)
Environmental
* Operating Temperature 10 to 40°C (50 to 104°F)
* Storage Temperature -20 to 60°C (-4 to 140°F)
* Operating Humidity 15 to 90% RH, non-condensing
Accessories
Most models: Reusable adult cuff, adult 3.5m cuff hose, ECG cable,
ECG 3-lead wires, SpO2 Durasensor® DS-100A, SpO2 extension cable
DOC-10, operation manual, power cord, rechargeable battery (1).
Available with: CO2 sampling set, printer paper, ECG 5-lead wires,
temperature probes, rolling stand, and a full size range of reusable and
disposable BP cuffs